Site Notice | Privacy Policy | Downloads | Shop | Contact

Terminal Unit Forano AGSS

ANAESTHETIC GAS SCAVENGING SYSTEM

System for safe disposal of excess anaesthetic gases and anaesthetic vapours from the clinical environment within a central medical gas supply system in line with DIN EN ISO 7396-2.

All-metal construction, symbols for monitoring operation, with external ejector for vacuum generation. Suction adjustable; single-handed operation when connecting and disconnecting, unlocking via the connector receptacle. Fully mounted in a stainless steel casing, with stainless steel front panel (for concealed or hollow wall installation). Design complies with DIN EN ISO 9170-2.

QUESTIONS?

Björn Rehr
+49 (0)40 / 73 93 57 - 0
E-Mail

  • TECHNICAL DATA
    Dimensions: 145 x 120 x 65 mm (WxHxD)
    Material: Brass; casing and front panel stainless steel
    Throughput: Min. 50 L/min at 500 kPa
    Inlet: Copper pipe 8x1 mm / flexible tube PA 6 mm
    Outlet: Copper pipe 15x1 mm / wave tube 15 mm
    Marking: Colour coding in line with DIN EN ISO 9170-2
    standard magenta
  • FORANO AGSS
    Forano AGSS, concealed / hollow wall 902.073
    Forano AGSS, ceiling pendants, with external ejector 902.074
    Forano AGSS, bed-head units 902.075
    Forano AGSS, surface mounting 902.076

Concealed version
175 x 175 mm


Surface version
130 x 174* x 80 mm (**plus approx. 200 mm Cu pipe)