Terminal Unit Forano DIN
INSTALLATION INTO BED HEAT UNIT
The unit is used to withdraw compressed gases and vacuum from a central medical gas supply system in line with DIN EN ISO 7396-1; integration of plugs and medical appliances with plug-in connections in line with DIN 13260-2. The Forano terminal unit complies with the requirements of DIN EN ISO 9170-1.
Advantages
- Two-part construction: gas-specific basic block and connector mounting
- Sophisticated design: all-metal actuator with laser labelling
- Easy installation and servicing: cartridge with sealing elements, replacement possible without blocking the station
- Unique marking: gas-type labelling – print labelling: chemical symbol + English + CE, colour coding: neutral or in line with DIN EN ISO 5359.
- Technical Data
Inlet: 8 mm copper pipe Operating pressure: 400 kPa to 500 kPa (overpressure) – compressed gases
< 60 kPa (absolute pressure) – vacuum - Trilux VS 100M (A) right/ Order numbers
Forano, O2, Trilux VS100M (A) type DIN / AGA / NF 903.210 Forano, AIR, Trilux VS100M (A), type DIN / AGA / NF 903.211 Forano, VAC, Trilux VS100M (A), type DIN / AGA / NF 903.212 Forano, N2O, Trilux VS100M (A), type DIN / AGA / NF 903.213 Forano, CO2, Trilux VS100M (A), type DIN / AGA / NF 903.215 Forano, special gas, Trilux VS100M (A) type DIN 903.216 Front part has to be ordered separately!
All front parts for terminal unit Forano DIN, neutral or DIN EN ISO 5359 colour coding, can be found here. - Trilux VS 100M (B) left/ Order numbers
Forano, O2, Trilux VS100M (B), type DIN / AGA / NF 903.220 Forano, AIR, Trilux VS100M (B), type DIN / AGA / NF 903.221 Forano, VAC, Trilux VS100M (B), type DIN / AGA / NF 903.222 Forano, N2O, Trilux VS100M (B), type DIN / AGA / NF 903.223 Forano, CO2, Trilux VS100M (B), type DIN / AGA / NF 903.225 Forano, special gas, Trilux VS100M (B) type DIN 903.226 Front part has to be ordered separately!
All front parts for terminal unit Forano DIN, neutral or DIN EN ISO 5359 colour coding, can be found here.