Site Notice | Privacy Policy | Downloads | Shop | Contact

HD - manifold

1 - 10-Fold

To connect one or more individual gas cylinders to a cylinder battery.

Every individual connection is equipped with a non-return valve, which prevents a return flow or running dry. A main shut-off valve allows separation of the entire side from the supply and the manifold can be depressurised via a bleed valve.

All components are high-pressure resistant (BAM tested) and thus withstand the operating pressure of 20,000 kPa (200 bar). Two cylinders in each case are connected as single or double versions via a distribution bend to the manifold.

Design

  • High pressure manifold 1 to 10-fold
  • Individual valves per connection
  • Main shut-off valve for the entire manifold
  • Bleed valve with solder connection

HD - distribution bend
For the high pressure connection between the cylinder valve and manifold. Version with compensating spiral, as manual connection or hexagonal nut, in a single or double version.

HD - connecting pipe
To connect the manifold with the switchover system.

QUESTIONS?

Björn Rehr
+49 (0)40 / 73 93 57 - 0
E-Mail

Export customers:
E-Mail

  • HD - manifold

    Technical data

    Inlet pressure max:20.000 kPa (200 bar)
    Operating temperature:+10° bis +40° C
    Separation between cylinders:300 mm

     

    Anbauschnellkupplung

    HD - manifold, 1-fold, complete327.301
    HD - manifold, 2-fold, complete 900.522
    HD - manifold, 3-fold, complete 900.523
    HD - manifold, 4-fold, complete 900.524
    HD - manifold, 5-fold, complete 900.525
    HD - manifold, 6-fold, complete 900.526
    HD - manifold, 7-fold, complete 900.527
    HD - manifold, 8-fold, complete 900.528
    HD - manifold, 9-fold, complete 900.529
    HD - manifold, 10-fold, complete 900.530
  • HD - distribution bend

    Usage
    For the high pressure connection between the cylinder valve and manifold. Version with compensating spiral, as manual connection or hexagonal nut, in a single or double version.

    Technical data

    Operating pressure max.:20.000 kPa (200 bar)
    Inlet:gas-specific
    Outlet:gas-specific

     

    HD - distribution bend

    HD - distribution bend, manual connection, O2, single 325.414
    HD - distribution bend, manual connection, O2, double 324.414
    HD - distribution bend, manual connection, AIR, single 325.524
    HD - distribution bend, manual connection, AIR, double324.514
    HD - distribution bend, manual connection, N2O, single325.415
    HD - distribution bend, manual connection, CO2, single325.426
    Other gases, connections and normson request
  • HD - connecting pipe

    Usage
    To connect the manifold with the switchover system.

    Technical data

    Operating pressure max.:20.000 kPa (200 bar)
    Inlet:G ¾"
    Outlet:G ¾"

     

    HD - connecting pipe

    HD - connecting pipe for 2x manifold327.304
    HD - connecting pipe, manifold with MC 2025 E / P324.010
    HD - connecting pipe, manifold with MC 2100 / 2050 E / P324.001
    HD - connecting pipe, manifold 1-fold with MC 2025 E / P324.015
    HD - connecting pipe, manifold with reserve panel324.013
    HD - connecting pipe, manifold 1-fold with HU 10325.732
    HD - connecting pipe, manifold with HU 10325.733
    HD - connecting pipe, manifold 1-fold with reserve panel 324.018
our Retailers